beautypg.com

B&G H2000 Pilot *DISCONTINUED* User Manual

Page 44

background image

h2000 User Manual

44

HB-0845-06

2.6.2 Rolling

5

Timer

As an alternative to the main settable timer, a ‘rolling 5’ is
provided. This simply cycles from 5:00 minutes to zero then
starts again counting down from 4:59, until stopped. The
same START, STOP and SYNC functions as used in the
settable timer are available in the CONTROL menu.

2.6.3 Timer Alarm Sounder

When the timer is counting down, the Audible Alarm
(optional, fitted to the h2000 Main Processor) will sound
every 10 minutes until the counter reaches 10 minutes to go,
the alarm sounder will then sound briefly at the following
intervals:

5:00, 4:00, 3:00, 2:00, 1:00, 0:30, 0:15, 0:10, 0:05 and 0:00.

2.6.4

Reset Trip Log

1.

Select TRIP LOG on the upper display.

2. Press

Scroll Down once, the lower display shows

CONTROL flashing.

3.

Press Enter, and then press Scroll Down
repeatedly until the display shows RESET
flashing.

4.

Press

Enter and the display shows the TRIP LOG

reset and RUN in the lower menu flashing.

5.

Press

Enter again and the display now shows the

TRIP LOG running.

6.

Press

Page to resume normal operation.

Each time you reset the TRIP LOG, the AVERAGE SPEED
resets and begins its calculation again. The control facility
for the Dead Reckoning functions work in the same manner.
The bearing and distance are linked, so that when one is
started, both start.