B&G H2000 Pilot *DISCONTINUED* User Manual
Page 209
HB-0845-06
209
The options in the DIAGNOSTICS Menu are described in
the following paragraphs, 6.1.2 to 6.1.3.
6.1.2 RES-SYS
Caution Do not use this option during normal
operation as all calibration values will be
lost
This allows individual units or the entire system to be reset.
The network node address of the unit to be reset is selected
using the Scroll Up and Scroll Down Keys and then Enter
pressed. The node allocations are as follows:
Individual Addresses
Node Address
Function
01
H
Depth
05
H
Wind
09
H
Performance
0D
H
Expansion
10
H
Halcyon
2000
Compass
11
H
to 12
H
(Typ. 12
H
)
Auto-Pilot
20
H
to 2F
H
FFDs
30
H
to 3F
H
Halcyon
FFDs
40
H
to 4F
H
20/20’s
50
H
to 5F
H
Pilot
FFDs
60
H
to 6F
H
NMEA
FFDs
112
H
to 127
H
Loadcell
Amplifiers
128
H
Tank Level Sensor