B&G H2000 Pilot *DISCONTINUED* User Manual
Page 195
HB-0845-06
195
nnn = number of node from which value is to be obtained.
1
- Depth
Board
5 to 8 - Wind Board
9 to 12 - RS232 or NMEA Board
13 to 16 - Expansion Boards
17 to 18 - Pilot Boards
255
- Broadcast
to
all
Boards
mmm = message type to be used
211
- Calibration
Value
1
212
- Calibration
Value
2
213
- Calibration
Value
3
214
- Calibration
Value
4
206
- Damping
Value
34
- High
Alarm
Value
33
- Low
Alarm
Value
32
- Sector
Alarm
Value
1
- Data
Value
fff = function number of value to be sent
This is a general purpose command for getting values from
any node (including the Performance Unit itself) and replies
with the value as follows:
Vnnn,mmm,fff,xx.xx(CR)
xx.xx = value
5.15.33 NMEA Sentence Output Rate Selection
#NS,p,fff,r(CR)
can be used to set the output rate of a specified NMEA
sentence, where:
p is the NMEA port number, 1 or 2
fff is the three-character NMEA sentence formatter
r is the desired output rate in Hz
Example: