B&G H2000 Pilot *DISCONTINUED* User Manual
Page 143
HB-0845-06
143
Boatspeed
Depth
Windspeed
Apparent
Wind
Angle
Magnified Wind Angle Compass Heading
Cross Track Error Trend*
Rudder Heel
Off
Course*
True
Wind
Angle
Note
•
Items marked with * are only available with the Halcyon
Display.
5.3.3 Analogue Indicator Configuration
If meters other than the defaults are chosen then it is
necessary to reconfigure the meter drive outputs from the
Computer Unit. This is done from any FFD as follows:
1.
Power up the system with the Enter Key pressed,
DIAGNOST appears.
2. Press
Scroll Up, CNFG SYS appears, press Enter
to select this option, now press Enter again to
select the METERS option.
3.
With OPTIONS flashing, press Enter, METER 1
appears, the Scroll Up Key is now used to scroll
through the meter drives (Refer to the installation
sheet to determine the meter options and their
respective meter drives).
4. With the appropriate meter drive flashing in the
top display, press Enter to reveal the current
option assigned to that meter. Pressing Scroll Up
at this stage, and then Enter again, will reveal the
METER 2 option. Repeating this process will
reveal the METER 3 and METER 4 options as
required.
5. With the meter number and option on display,
press Enter, the lower text will flash. Use Scroll
Down to scroll through the options until the
appropriate one (e.g. DEPTH) is shown. Pressing