beautypg.com

B&G H2000 Pilot *DISCONTINUED* User Manual

Page 143

background image

HB-0845-06

143

Boatspeed

Depth

Windspeed

Apparent

Wind

Angle

Magnified Wind Angle Compass Heading
Cross Track Error Trend*
Rudder Heel
Off

Course*

True

Wind

Angle

Note

Items marked with * are only available with the Halcyon

Display.

5.3.3 Analogue Indicator Configuration

If meters other than the defaults are chosen then it is
necessary to reconfigure the meter drive outputs from the
Computer Unit. This is done from any FFD as follows:

1.

Power up the system with the Enter Key pressed,
DIAGNOST appears.

2. Press

Scroll Up, CNFG SYS appears, press Enter

to select this option, now press Enter again to
select the METERS option.

3.

With OPTIONS flashing, press Enter, METER 1
appears, the Scroll Up Key is now used to scroll
through the meter drives (Refer to the installation
sheet to determine the meter options and their
respective meter drives).

4. With the appropriate meter drive flashing in the

top display, press Enter to reveal the current
option assigned to that meter. Pressing Scroll Up
at this stage, and then Enter again, will reveal the
METER 2 option. Repeating this process will
reveal the METER 3 and METER 4 options as
required.

5. With the meter number and option on display,

press Enter, the lower text will flash. Use Scroll
Down
to scroll through the options until the
appropriate one (e.g. DEPTH) is shown. Pressing