h2000 User Manual
132
HB-0845-06
CLINOMETER
(HEEL)
690-00-004
BAROMETRIC
PRESSURE
SENSOR
690-00-007
21
22
23
24
25
26
27
GROUND
SENSOR SUPPLY 6.5V DC
AIR TEMP. INPUT
LINEAR 1 INPUT (HEEL)
LINEAR 2 INPUT (TRIM)
LINEAR 3 INPUT (BARO)
LINEAR 4 INPUT (SPARE)
BLUE
RED
GREEN
GREEN
38
41
BARO. SENSOR GROUND
BARO. SENSOR SUPPLY
BLUE
RED
Ensure the boat is level and steady, a sheltered berth is
required for best results.
For HEEL angle sensor select a transverse vertical bulkhead.
For TRIM angle sensor select a longitudinal vertical bulkhead.
For correct indication of port or starboard heel angle,
mount the unit so that the top surface is horizontal and
level, with the lid of the unit (labelled) facing aft.
Heel angle calibration should be carried out to ensure
accuracy. Refer to Manual, Section 4.
Mount the unit on a suitable vertical bulkhead, in a dry
location, protected from the direct influences of the
elements ie. rain, salt spray and extremes of temperature.
Do not mount the sensor in a sealed compartment.
MAIN PROCESSOR
TERMINALS
20
21 22
23 24
25 26
27
38
41
TERMINAL
FUNCTION
CABLE & WIRE COLOUR
CLINOMETER INSTALLATION
BAROMETRIC PRESSURE SENSOR INSTALLATION
CLINOMETER SENSOR
PRESSURE SENSOR
CABLE ATTACHED
CABLE ATTACHED
CLINOMETER AND BAROMETRIC PRESSURE
SENSOR INSTALLATION SHEET