beautypg.com

H2000 user manual – B&G H2000 Pilot *DISCONTINUED* User Manual

Page 132

background image

h2000 User Manual

132

HB-0845-06

CLINOMETER

(HEEL)

690-00-004

BAROMETRIC

PRESSURE

SENSOR

690-00-007

21

22

23

24

25

26

27

GROUND

SENSOR SUPPLY 6.5V DC

AIR TEMP. INPUT

LINEAR 1 INPUT (HEEL)

LINEAR 2 INPUT (TRIM)

LINEAR 3 INPUT (BARO)

LINEAR 4 INPUT (SPARE)

BLUE

RED

GREEN

GREEN

38

41

BARO. SENSOR GROUND

BARO. SENSOR SUPPLY

BLUE

RED

Ensure the boat is level and steady, a sheltered berth is

required for best results.

For HEEL angle sensor select a transverse vertical bulkhead.

For TRIM angle sensor select a longitudinal vertical bulkhead.

For correct indication of port or starboard heel angle,

mount the unit so that the top surface is horizontal and

level, with the lid of the unit (labelled) facing aft.

Heel angle calibration should be carried out to ensure

accuracy. Refer to Manual, Section 4.

Mount the unit on a suitable vertical bulkhead, in a dry

location, protected from the direct influences of the

elements ie. rain, salt spray and extremes of temperature.

Do not mount the sensor in a sealed compartment.

MAIN PROCESSOR

TERMINALS

20

21 22

23 24

25 26

27

38

41

TERMINAL

FUNCTION

CABLE & WIRE COLOUR

CLINOMETER INSTALLATION

BAROMETRIC PRESSURE SENSOR INSTALLATION

CLINOMETER SENSOR

PRESSURE SENSOR

CABLE ATTACHED

CABLE ATTACHED

CLINOMETER AND BAROMETRIC PRESSURE

SENSOR INSTALLATION SHEET