beautypg.com

B&G H2000 Pilot *DISCONTINUED* User Manual

Page 184

background image

h2000 User Manual

184

HB-0845-06

where r is

the

row

number

(0..9)

cc

is

the

column

number

(01..22)

uu.u is the true wind speed set for this row
vv.vv is the boat speed
ww.ww is the optimum upwind vmg
xxx is the true wind angle for upwind vmg

yy.yy is

the

optimum

downwind

vmg

zzz is the true wind angle for downwind
vmg

Because output lines can only be a maximum of 80
characters it takes several lines to output a complete row.
Each line begins with

PR,r,cc....

to indicate which row and column follows.

In a similar way, the command:

#PO(CR)

outputs the entire table, row by row, in the above format.

5.15.16 Input Polar Table Value

####

PI,s,nn,yy.yy(CR)

s = 0 - 9 (as in previous command)
nn = 02 - 22 (as in previous command)

This command permits any single element of the polar table
to be changed.

Example:

The command

####

PI,7,05,07.45(CR)

Will cause the polar table element corresponding to a wind
speed of 20 knots and a true wind angle of 50 degrees to be
changed from 7.40 Knots to 7.45 Knots.

Likewise command

####

PI,0,22,150(CR)