Rockwell Automation Motion Analyzer Software User Manual
Page 197

Rockwell Automation Publication MOTION-UM004B-EN-P - October 2012
197
Sizing Your System
Chapter 2
Enter the following parameters to further narrow the motor options and help you
decide which motor is best for your application.
Table 116 - Motor Series Selection Properties
Figure 147 - Compatible Motor Series
Table 117 - Motor Series Legend (refer to
Parameters
Description
Applications
Requirements
(label 1 in
Maximum Speed
Values are based on the information you entered in the previous tabs. These values cannot be
changed in this tab.
Continuous Torque
Peak Torque
Ambient
Temperature
Ambient temperature for the application environment.
Altitude
Altitude for the application environment.
Brake
From the Brake pull-down menu, choose YES or NO depending on your application.
Displays the available motor series. As application requirements are entered or motor series are selected, incompatible
motors are dimmed and crossed-out (boxed in red in
Symbol
Description
By hovering over this symbol, the particular motor series’ voltage ratings are displayed.
Indicates that the motor series supports the application.
Indicates that the motor series support for the application is marginal.
Indicates that the motor series is not recommended for the application.
Indicates that the motor series is incompatible with the application.