Sizing Your System

Chapter 2

Click

to use the Quick Profile tool. A trapezoidal load profile is entered into

the data grid after clicking Apply.

Figure 94 - Quick Profile Tool

Table 69 - Quick Profile Tool (refer to

Figure 94

)

Parameter

Description

Move Angle

Angle through which the load profile takes place.

Move Time

Time through which the load profile takes place.

Wait Time

Length of time to wait before the specified index move repeats.

Velocity Pk/Ave

Velocity Peak/Average. The following values apply:
2 = triangle; minimum peak torque
1.5 = equal trapezoid; minimum RMS (root mean squared) torque
1 = infinite acceleration; not useable
If the start velocity is non-zero, the peak velocity may be adjusted by the program to avoid
crossing the zero line.

Accel.Pk/Ave

Acceleration Peak/Average. The following values apply:
1 = Trapezoidal acceleration
2 = S-curve acceleration
>1 or <2 = partial S-curve