Configuring the Outer Control Loop Reference

9-1

C

HAPTER

9

Configuring the Outer

Control Loop Reference

The outer control loop (

OCL

) is typically used to provide dancer position or tension

control in a web processing system.

Configuring the outer control loop reference includes setting up the following:

Tension setpoint

Dancer loading

Refer to figure A.17 in Appendix A of the software manual (D2-3444) as you configure
the outer control loop reference.

9.1

The Tension Setpoint

þ

To configure the tension setpoint when

OCL

SELECT

(P.817) is set to

CURRENT

or

TENSION

:

Set

TENSION

SETPOINT

SEL

(P.855) to select the source of the tension

reference. The choices are:

REGISTER

- Provides a tension reference based on the register value of

TENSION

SETPOINT

(P.854).

ANALOG

- The tension reference is developed by the analog input signal at

terminals 50 and 51 on the Regulator board and is scaled by parameters

TENSION

SETPT

SIG

TYPE

(P.413),

TENSION

SETPOINT

ZERO

(P.414), and

TENSION

SETPOINT

GAIN

(P.415).

Use This Chapter for These Applications:

Constant Diameter Current Regulator (Section 9.1)

Variable Diameter Current Regulator (Section 9.1)

Constant Diameter Position Regulator

Variable Diameter Position Regulator

Constant Diameter Tension Regulator (Section 9.1)

Variable Diameter Tension Regulator (Section 9.1)

Generic

Range:

REGISTER

,

ANALOG

P.855 =