WebPak 3000 DC Drive Application Workbook, Version 1.1

3.2.2 The S-CURVE Block

The output of the

LIMIT

block is the input to the

S

-

CURVE

block.

SPEED

RAMP

BYPASS

(P.112) controls the output of the

S

-

CURVE

block. Refer to figure A.5 in Appendix A of

the software manual (D2-3444).

þ

To set up the

S

-

CURVE

block:

Set

SPEED

RAMP

BYPASS

(P.112). The choices are:

ON

- Bypasses the

S

-

CURVE

block, and the output of the

LIMIT

block is used as

the value of

SPEED

RAMP

OUTPUT

(P.199). (This value can also be read as

SPEED

RAMP

INPUT

TP

(P.198)).

Note that setting

SPEED

RAMP

BYPASS

to

ON

will negate the use of inertia

compensation when

INERTIA

COMP

SELECT

(P.221) is set to

CALCULATOR

. To

use the drive’s on-board programmed inertia compensation function, P.112
must be set to

OFF

.

OFF

- The output of the

S

-

CURVE

block is used as the value of

SPEED

RAMP

OUTPUT

(P.199).

þ

If

SPEED

RAMP

BYPASS

(P.112) =

OFF

:

Set

S

-

CURVE

ROUNDING

(P.014) to specify the smoothing of the

S

-

CURVE

block output.

The range is 0 to 50%. A 0% setting results in a linear ramp function. A
50% setting results in the entire ramp being smoothed 50% at the
beginning and 50% at the end, which extends the ramp time.

Set

STOP

MODE

SELECT

(P.114). The choices are:

RAMP

-

RAMP

STOP

DECEL

TIME

(P.018) or

DECELERATION

TIME

(P.002) is used.

Note that if the trim mode previously selected in

TRIM

MODE

SELECT

(P.110) is

PROPORTIONAL

, under a ramp stop configuration the ramp time will be

modified in the same way as the acceleration ramp time.

COAST

/

DB

- If a coast stop or a dynamic braking stop is initiated, the main

contactor will open immediately, and the drive will coast or dynamically brake
to zero speed.

CURRENT

LIMIT

- All deceleration ramps are bypassed.

þ

If

STOP

MODE

SELECT

(P.114) =

RAMP

, then

STOP

DECEL

SELECT

(P.122)

must be set to P.002 or P.018:

Set

STOP

DECEL

SELECT

(P.122) to specify which deceleration time will

be used for a ramp stop sequence. The ramp deceleration time for
stopping can be set independent of the normal running deceleration
ramp.

Note that if an external ramped reference is used, the deceleration rate
for the internal speed ramp (

S

-

CURVE

block) should be set so that it is

faster than the deceleration rate of the external speed reference ramp.

Range:

ON

,

OFF

P.112 =

Range: 0 to 50%

P.014 =

%

Range:

RAMP

,

COAST

/

DB

,

CURRENT

LIMIT

P.114 =