Rockwell Automation WebPak 3000 DC Drive Application Workbook Version 1.1 User Manual
Page 38
5-4
WebPak 3000 DC Drive Application Workbook, Version 1.1
▲
Set
FIELD
INPUT
8 (P.537).
▲
Set
FIELD
CURRENT
1 (P.522).
▲
Set
FIELD
CURRENT
2 (P.523).
▲
Set
FIELD
CURRENT
3 (P.524).
▲
Set
FIELD
CURRENT
4 (P.525).
▲
Set
FIELD
CURRENT
5 (P.526).
▲
Set
FIELD
CURRENT
6 (P.527).
▲
Set
FIELD
CURRENT
7 (P.528).
▲
Set
FIELD
CURRENT
8 (P.529).
▲
Set
FIELD
SHAPING
LAG
(P.538) to specify a lag frequency for the field
shaping output.
▲
Set
FIELD
LOSS
THRESHOLD
(P.512). This is the value of motor field current that
is compared with
FIELD
FEEDBACK
(P.589), and is set as a percentage of
MOTOR
HOT
FLD
AMPS
(P.510). It is usually set for 85% of the motor nameplate
field weakened current to check for field loss. The choices are:
50 to 100% of
MOTOR
HOT
FLD
AMPS
(P.510) when
FEEDBACK
SELECT
(P.200) is
set to
ARMATURE
VOLT
.
0 to 100% of
MOTOR
HOT
FLD
AMPS
(P.510) when
FEEDBACK
SELECT
(P.200) is
set to
DC
TACH
or
ENCODER
.
.
Range: 0 to 5000
RPM
P.537 =
RPM
Range: 0.00 to
MOTOR
HOT
FLD
AMPS
(P.510)
P.522 =
AMPS
Range: 0.00 to
MOTOR
HOT
FLD
AMPS
(P.510)
P.523 =
AMPS
Range: 0.00 to
MOTOR
HOT
FLD
AMPS
(P.510)
P.524 =
AMPS
Range: 0.00 to
MOTOR
HOT
FLD
AMPS
(P.510)
P.525 =
AMPS
Range: 0.00 to
MOTOR
HOT
FLD
AMPS
(P.510)
P.526 =
AMPS
Range: 0.00 to
MOTOR
HOT
FLD
AMPS
(P.510)
P.527 =
AMPS
Range: 0.00 to
MOTOR
HOT
FLD
AMPS
(P.510)
P.528 =
AMPS
Range: 0.00 to
MOTOR
HOT
FLD
AMPS
(P.510)
P.529 =
AMPS
Range: .01 to 13.96
RAD
/
S
P.538 =
RAD
/
S
!
ATTENTION: Setting
FIELD
LOSS
THRESHOLD
(P.512) too low can
eliminate field loss protection. Set P.512 such that field loss protection
will shut the drive down before it reaches unsafe speed. Failure to
observe this precaution could result in severe bodily injury or loss of life.
Range: 50 to 100% of P.510 or 0 to 100% of P.510
P.512 =
%