Chapter 5 Configuring FactoryTalk Historian
88
Rockwell Automation Publication HSE-IN025A-EN-E–September 2013
NOTE
In order to assign the activations to a FactoryTalk Historian SE
server, the server must be added to the FactoryTalk Directory. See
"Adding the Server to the FactoryTalk Directory (page 78)" for more
information.
To assign the license activations to the server:
1. Go to
Start > All Programs > Rockwell Software > FactoryTalk
Administration Console.
2. In the Select FactoryTalk Directory dialog box, select
Network, and click OK.
3. In the Explorer tree, expand System > Connections >
Historical Data.
4. Right-click the name of the server to which you want to assign
the license activations, and click Properties.
5. In the Historian Server Connection Properties dialog box,
click the Licensing tab. The table displayed in the tab provides
the following information for the selected server:
Item
Description
Activation
The type of the license activation.
Total
The total number of license activations of the given type.
In Use
The number of license activations of the given type that are
used by other Historian servers.
Assigned
The number of license activations of the given type that are
assigned to the selected server.
6. To assign a license activation to the server, type a number in
the Assigned column for the selected license activation. The
number shows how many licenses of the selected type will be
assigned to the server.
Assigning License Activations
to the Historian Server