To distribute licenses between the license pools:

1. Calculate the

value.

= Max (Min(1000, ∑ ),
20% * ∑ )

= Max (Min(1000, 12000), 20% *
12000)

= Max (Min(1000, 12000), 2400)
= Max (1000, 2400)
= 2400

2. Calculate the number of licenses for the Rockwell license pool.

= ∑ + ∑ licenses> -
= 5000 + 12000 - 2400
= 14600

3. Calculate the number of licenses for the General license pool.

= ∑ +
+ ∑

= 500 + 2400 + 0
= 2900

In this example, the total of 17500 licenses has been distributed in
the following way:

Licenses and license pools

Values

License total

17500

Rockwell license pool

14600

General license pool

2900