To specify the FactoryTalk Directory server location:
1. Run the FactoryTalk Historian SE installation DVD.
2. On the welcome page of the installation wizard, click
Install
FactoryTalk Historian Site Edition > Install FactoryTalk
Services Platform > Specify FactoryTalk Directory Server
Location.
The FactoryTalk Directory Server Location Utility dialog
box appears.
1. In the FactoryTalk Directory Server Location Utility
dialog box, verify that it points to the correct computer that
hosts the FactoryTalk Directory server.
NOTE
On the computers that have FactoryTalk Services Platform
installed, you can open the Specify FactoryTalk
Directory Server Location Utility dialog box also from
Start > All Programs > Rockwell Software > FactoryTalk
Tools > Specify FactoryTalk Directory Location.
FactoryTalk Activation Manager allows you to download activation
files using an Internet connection, and transfer the activation files to
a computer that does not have an Internet connection. Install this
software on the same computer as the FactoryTalk Directory server.
To install the FactoryTalk Activation Manager:
1. Run the FactoryTalk Historian SE installation DVD.
2. On the welcome page of the installation wizard, click
Install
FactoryTalk Historian Site Edition > Install FactoryTalk
Services Platform > Install FactoryTalk Activation.
The FactoryTalk Activation Manager installation wizard
appears with a list of prerequisite packages.
3. Click Continue.
Install FactoryTalk Activation
Manager