Chapter 6 Troubleshooting FactoryTalk Historian
120
Rockwell Automation Publication HSE-IN025A-EN-E–September 2013
Error number
Description
200
The user has declined to make the changes to the
configuration of Windows Firewall.
320
The network connection specified in WFCU could not be
found.
Cause: No network connection is configured.
Resolution: Configure the network connection and then
configure Windows Firewall.
See "Configuring Windows Firewall with WFCU (page 121)"
for details.
• The errors that may appear if you use another firewall utility to
configure network security on the computer with FactoryTalk
Historian installed:
Error number
Description
10
The version of Windows Firewall is not supported by WFCU.
100
Some parameters of the WFCU configuration are missing.
110
Some parameters of the WFCU configuration are incorrect.
120
The .WFCU file contains incorrect data.
130
The .WFCU file is missing.
300
The configuration of Windows Firewall is not supported by
WFCU.
310
The .WFCU file contains incorrect configuration settings.
400
The Microsoft Firewall service is stopped.
-999
Rockwell Windows Firewall Configuration Utility (WFCU)
could not be found.
See "Configuring Firewall for FactoryTalk Historian (page
75)" for details.
If the error message does not contain the error number, refer to the
FactoryTalk Historian log for the error details.