Dpi alarm object, Class code 0x0098 – Rockwell Automation 294D ArmorStart LT Distributed Motor Controller DeviceNet Version - User Manual User Manual
Page 235

Rockwell Automation Publication 290D-UM001A-EN-P - June 2012
235
CIP Information
Appendix B
DPI Alarm Object
CLASS CODE 0x0098
This object provides access to warning information within the device.
The following class attributes will be supported.
A single instance of the DPI Alarm Object will be supported.
The following common services will be implemented for the DPI Fault Object.
The table below lists Fault Codes, Fault Text, and Fault Help Strings.
Attribute ID
Access Rule
Name
Data Type
Value
1
Get
Class Revision
UINT
1
2
Get
Number of Instances
UINT
1
3
Set
Alarm Cmd Write
USINT
0=NOP; 1=Clear Alarm; 2=Clear Queue
4
Get
Alarm Instance Read
UINT
The instance of the Fault Queue Entry containing information
about the fault that tripped the device.
6
Get
Number of Recorded Alarms
UINT
The number of faults recorded in the fault queue.
Attribute ID
Access Rule
Name
Data Type
Value
0
Get
Full/All Info
Alarm Code
Alarm Source
DPI Port Number
Device Object Instance
Alarm Text
Alarm Time Stamp
Timer Value
Timer Descriptor
Help Object Interface
Alarm Data
Struct of:
UINT
Struct of:
USINT
USINT
STRING
Struct of:
ULINT
WORD
USINT
See Tables below
0
See Tables below
1
Get
Basic Info
Alarm Code
Alarm Source
DPI Port Number
Device Object Instance
Alarm Time Stamp
Timer Value
Timer Descriptor
Struct of:
UINT
Struct of:
USINT
USINT
Struct of:
ULINT
WORD
See Tables below
0
3
Get
Help Text
STRING
See Tables below
Service Code
Implemented for:
Service Name
Class Instance
0x0E
Yes
Yes
Get_Attribute_Single
0x10
Yes
No
Set_Attribute_Single
Table 32 - Fault Codes, Fault Text, and Fault Help Strings for ArmorStart LT
Warning
Code
Warning Text
Help Text
1
Warning 1
—
2
Warning 2
—
3
Motor Overload
Overload warning level has been exceeded.