Chapter 4
Bulletin 290D/291D/294D Programmable Parameters
ConsumedIOAssy
Selects the format of the I/O data
consumed
290 default = 150
Parameter Number
101
Access Rule
SET
Data Type
USINT
Group
Network
Units
–
Minimum Value
3
Maximum Value
150
Default Value
150
ProducedIOAssy
Selects the format of the I/O data
consumed
290 default = 151
Parameter Number
102
Access Rule
SET
Data Type
USINT
Group
Network
Units
–
Minimum Value
52
Maximum Value
151
Default Value
151
AutoRunZip
Enables this device to produce COS
messages on powerup
0=Disable
1=Enable
Parameter Number
103
Access Rule
SET
Data Type
BOOL
Group
ZIP
Units
–
Minimum Value
0
Maximum Value
1
Default Value
0
ZoneProducedEPR
Expected Packet Rate for producing Zip
COS connection
Parameter Number
104
Access Rule
SET
Data Type
UINT
Group
ZIP
Units
msec
Minimum Value
1
Maximum Value
65535
Default Value
75