Rockwell Automation 294D ArmorStart LT Distributed Motor Controller DeviceNet Version - User Manual User Manual
Page 118

118
Rockwell Automation Publication 290D-UM001A-EN-P - June 2012
Chapter 4
Bulletin 290D/291D/294D Programmable Parameters
Zone4EPR
Expected Packet Rate for Zone 4
consuming connection
Parameter Number
133
Access Rule
SET
Data Type
UINT
Group
ZIP
Units
msec
Minimum Value
0
Maximum Value
65535
Default Value
75
Zone1Control
Enables/Disables options for Zone 1
control
Parameter Number
134
Access Rule
SET
Data Type
BYTE
Group
ZIP
Units
–
Minimum Value
0
Maximum Value
0x3F
Default Value
0x02
Bit
Function
7
6
5
4
3
2
1
0
— — — — — — —
X
SecurityEnable
— — — — — —
X
—
COSCnxn
— — — — —
X
— —
PollCnxn
— — — —
X
— — —
StrobeCnxn
— — —
X
— — — —
MulticastPoll
— —
X
— — — — —
FragmentedIO
X
X
— — — — — —
Reserved
Zone2Control
Enables/Disables options for Zone 2
control
Parameter Number
135
Access Rule
SET
Data Type
BYTE
Group
ZIP
Units
–
Minimum Value
0
Maximum Value
0x3F
Default Value
0x02