beautypg.com

AT&T System 25 User Manual

Page 403

background image

APPENDIX F: Administration Error Messages

ERROR MESSAGE

AND DESCRIPTION

POSSIBLE SOLUTION

7 0 5 4 : out of space

System speed digit pool is full.

no more room in digit
p o o l

7 2 0 0 : entry out of range

Invalid TARGET value specification.

RS232 value out of range

Target value should be 1-4. See:

MENU = 10 (RS232)

7 2 0 2 : inappropriate request

ACTION = 0 under MENU = 10

improper procedure

(RS232) is invalid.

7 2 0 3 :

incorrect entry

MENU = 10 (RS232) ACTION = 1

logical channel out of

DATA = must be 1-4 (anything else

r a n g e

is invalid.)

7204:

incorrect entry

MENU = 10 (RS232) ACTION = 2

return delay out of range

DATA = must be 0-2

7206:

incorrect entry

MENU = 10 (RS232) ACTION = 3

incorrect baud rate

DATA = baud rates must be 300,
1200, 4800, 9600.
Legal baud rates for Administration

and Maintenance are 1200, 4800,
9600. Legal baud rate for SMDR is
1200. Legal baud rate for Tape is
1 2 0 0 .

7 3 0 0 :

incorrect action number

Under Save/Restore, MENU = 9

data must be 1,2,3,10 or

Action values must be 1,2,3,10, or

2 0

2 0 .

7 3 0 2 : inappropriate request

Cannot administer system during

can’t update translation -

tape backup.

tape lockout

7 4 0 0 :

incorrect entry

MENU = 10 (RS-232) TARGET = 3

data must be 1 or 4 only

ACTION = 1 DATA = 2 or 3
SMDR output can come out of the

NOTE: Above is

tape port.

statement is wrong.

data must be 2 or 3 only

F-25