APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTION
POSSIBLE SOLUTION
7 0 5 4 : out of space
System speed digit pool is full.
no more room in digit
p o o l
7 2 0 0 : entry out of range
Invalid TARGET value specification.
RS232 value out of range
Target value should be 1-4. See:
MENU = 10 (RS232)
7 2 0 2 : inappropriate request
ACTION = 0 under MENU = 10
improper procedure
(RS232) is invalid.
7 2 0 3 :
incorrect entry
MENU = 10 (RS232) ACTION = 1
logical channel out of
DATA = must be 1-4 (anything else
r a n g e
is invalid.)
7204:
incorrect entry
MENU = 10 (RS232) ACTION = 2
return delay out of range
DATA = must be 0-2
7206:
incorrect entry
MENU = 10 (RS232) ACTION = 3
incorrect baud rate
DATA = baud rates must be 300,
1200, 4800, 9600.
Legal baud rates for Administration
and Maintenance are 1200, 4800,
9600. Legal baud rate for SMDR is
1200. Legal baud rate for Tape is
1 2 0 0 .
7 3 0 0 :
incorrect action number
Under Save/Restore, MENU = 9
data must be 1,2,3,10 or
Action values must be 1,2,3,10, or
2 0
2 0 .
7 3 0 2 : inappropriate request
Cannot administer system during
can’t update translation -
tape backup.
tape lockout
7 4 0 0 :
incorrect entry
MENU = 10 (RS-232) TARGET = 3
data must be 1 or 4 only
ACTION = 1 DATA = 2 or 3
SMDR output can come out of the
NOTE: Above is
tape port.
statement is wrong.
data must be 2 or 3 only
F-25