beautypg.com

AT&T System 25 User Manual

Page 385

background image

APPENDIX F: Administration Error Messages

ERROR MESSAGE

AND DESCRIPTION

1069:

incorrect facility type
incompatible with board

t y p e

1 0 7 0 : facility type out

of range

must be 3-4 digits

POSSIBLE SOLUTION

Board and features do not mix.

Check slot location for correct
board or not compatible with the
already entered types on the board.

Must be 3 or 4 digits.

1071:

inappropriate request
name does not exist

Name does not exists. Go to
MENU 8 (Search)

ACTION = 1 DATA = 40
ACTION = 2 DATA = PDC

Hit c to continue to search for name
associated with PDC, DDC, FPDC,

or DGC.

1072:

PDC out of range

System 25 dial codes may have

can’t exceed 4 digits

1,2,3 or 4 digits only.

1 0 7 3 : incorrect entry

You are administering a character

must begin with quote

string and must begin with quotes.

1 0 7 4 :

incorrect action number

I

Cannot update under action zero.

can’t update with 0

1075:

entry out of range

data must be 28 digits or

l e s s

System Speed Dialing numbers
must be 28 digits or less.

1077:

incorrect entry

5 zeros are never a legal entry.

5 zeroes always incorrect

1 0 7 8 :

incorrect entry
leading zeroes not

allowed

Leading zeros are not allowed for

Toll Call Allowed Lists.

1079:

incorrect action number

Item not installed, cannot enter

can’t exceed 2 with

items greater then 2.

unequipped facility

1080:

incorrect entry

I

Item must be 0 for removal.

must be 0 for removal

1081:

at installation max

System maximum of 109 MET sets.

109 MET sets

1 0 8 2 : inappropriate request

TT generator already

installed

TT generator already exists at this
location

F-7