MAINTENANCE

ERROR MESSAGE

AND DESCRIPTION

POSSIBLE SOLUTION

S e r v i c e Circuit

Test

Failed:

Check TDM bus terminator and

Service Circuit demand test failed

cabinet interconnect cables. If the

on the DTMF receivers.

problem persists, replace ZTN85

or ZTN131 (R3).

Signaling Lead Fault: Auxiliary

C h e c k

wiring of

e x t e r n a l

Trunk CP is expecting a ground

equipment per Figure 4-7.

from external equipment but none
is detected.

S l o t

Configuration

Error:

This condition can be resolved by

(STARLAN Interface CP) This

moving the ZTN84 port CP to

error means that another ZTN84

another slot in the carrier.

port CP is on the STARLAN
NETWORK and has the same
physical address.

System Lock-Up: This error is

Usually, no

action required;

logged by the task supervisor if,

however if

problem persists,

during scheduling of tasks, no

replace CPU/Memory CP.

messages have been read for at
least 60 seconds. This causes a
restart of the system.

System Restart: System locked

Check the power supply voltages

up in a software task. The “Port

per Figure 4-2. If problem persist,

Number” entry in the log is the

the CPU/Memory CP could be

task at fault.

defective.

Translation Memory Test Failed:

Check if Cold Start error has

Memory translation checksum test

occurred.

Reload translations

f a i l e d .

from tape per the procedure in
Administration Manual. If the
problem

persists,

c h e c k o r

replace CPU/Memory CP.