APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTlON
POSSIBLE SOLUTION
1 0 1 7 :
inappropriate request
Cap already installed
system already has Direct
C A P
ACTION = 1 (Cap)
Go to MENU 8 (Searches)
ACTION = 1 DATA = 18
ACTION = 2 DATA = 309 or 310
ACTION = 3 DATA = 0
1 0 1 8 : inappropriate request
Must remove secondary CAP before
must remove secondary attempting to remove the first CAP.
CAP first
1 0 1 9 :
incorrect action number
Check if the ACTION value taken is
does not exist or used
legal.
improperly
1 0 2 0 : inappropriate request
Trying to administer features to a
primary or secondary
secondary CAP that does not exist.
CAP does not exist
1021:
at installed max
At the maximum number of stations
-200 stations
allowed by the system.
1022:
at installed max
At the maximum number of trunks
-104 trunk
allowed by the system.
1023:
button function code
Button station out of range for
out of range
terminal type code. Check station
does not exist or used
for button range. (invalid button
improperly
function code)
1 0 2 4 :
at installed max
At system maximum of 300 FPDCs.
-300 FPDCs
1025:
at installed max -199
At system maximum of 199 EMT
EMT sets
s e t s .
1026:
at installation max
Maximum of 111 ATL sets, 2 of
-96 ATL set
which have to be CAPS
1027:
at installed max
At system maximum of 104
-104 trunk
ground-start trunks.
1028:
at installed max
At system maximum of 104 loop-
-104 trunk
start trunks.
1029:
at installed max
At system maximum of 104 DID
-104 trunk
t r u n k s .
1 0 3 0 :
at installed max
At system maximum of 32 TIE
-32 Tie trunk
trunks.
F-3