MAINTENANCE

ERROR MESSAGE

AND DESCRIPTION

P O S S I B L E S O L U T I O N

AC Power Failure: An indication

Check plug at wall receptacle. If

that ac power has been lost (for

this error occurs more often than

example, plug removed from a

the building power outages, check

wall receptacle, building power

connection to wall.

down for more than a quarter of a

second, etc.). If power is lost from

the first cabinet, the ETU will be
triggered.

Alarm Log Overflow: The error

Correct indicated errors, and then

logs are full and no more errors

remove entries from the Transient

can be written to them. This error

Error Log to free-up space.

is kept, however, to alert you of

the fact.

A r c h

Angel

Insane

Restart:

Make sure ZTN85 or ZTN131 (R3)

Clocks may be missing from the

circuit pack (CP) is installed.

TDM bus.

Check the inter-cabinet cables,

bus terminator and back plane for
bent pins. Reseat a port CP that
is in the same cabinet as ZTN85

or ZTN131 (R3). If it does not
power up,

replace

ZTN85 or

ZTN131 (R3). If it does but
p r o b l e m

persists,

replace

CPU/Memory CP.

Arch Angel Interrupt Restart:

Possible software problem. If this

System

restarted

due to

error occurs frequently, check the

CPU/Memory problem.

CPU/Memory CP.

Bad Oat Device:

(STARLAN

Recoverable; no action required.

Interface CP) This error is an

isolated transient condition.

4-33