MAINTENANCE

ERROR MESSAGE

AND DESCRIPTION

POSSIBLE SOLUTION

Trunk Call Dropped: A call that

Normally, no action required;

had been up on a trunk for more

however, if

problem persists,

than 9 hours has been detected

perform trunk test call per Trunk

by an audit and dropped. The

Troubles procedure in this Part.

port associated with the error

Also, check the CO disconnect

identifies the trunk in question.

and trunk timing.

Trunk Call Too Long: An audit

This error is removed when a

found a call that had been up on a

“Trunk Call Dropped” error is

trunk for more than 5 hours and

logged. Normally, no action is

logged this error to alert the user

required, and system will recover

of it.

in 4 hours. However, if a problem
does exist, check the associated

trunks per Figure 4-3. Also check
for a trunk to trunk call.

Unable To

S e n d Down-link

If problem persists, check or

Message:

Down-link message

replace CPU/Memory CP.

q u e u e is full.

This condition

means that messages to CPs may
be lost.

Unexpected

C o m m a n d :

Recoverable; no action required.

(STARLAN Interface CP) This
error is an

isolated transient

condition.

Unexpected interrupt: (STARLAN

Normally, no action required;

Interface CP) This error is an

however, if this error occurs too

isolated transient condition.

frequently, a permanent alarm will
be generated and the CP should
be checked.

4-45