beautypg.com

AT&T System 25 User Manual

Page 217

background image

MAINTENANCE

ERROR MESSAGE

AND DESCRIPTION

POSSIBLE SOLUTION

On-HookBeforeReady To Receive
Digits: For a tie trunk with delay
dial or wink

start—after the

handshake is complete, a 50-ms

guard time must pass before
digits are received. If the far-end
goes on-hook before guard time
elapses, this message is logged.

On-Hook Before Wink: For a tie
trunk with delay dial or wink
start—if the far end goes on-hook
(possibly indicating the beginning
of a rotary dial digit) before the
wink handshake is completed, the
error is logged.

A disconnect

sequence is started, and the call
may be dropped.

Recoverable; no action required.

If this problem persists, check the

tie trunk configuration (see Figure
4-6).

On-Hook During Wink: This error
indicates that digits are being sent
by the far end before the switch is
ready to receive them.

The two switches are probably not
compatible.

Check

the

configuration of each switch.

Physical

a n d

Logical Type

Mismatch: (Other than CPU or

Memory) Port CP plugged into

wrong slot.

Port CP in Unadministered Slot:

(Other than CPU/Memory) Port CP
inserted into a slot that is not
translated or CP inserted into
wrong slot.

Change translations to reflect the
new CP, or install the proper CP.

Translate slot, or remove CP. If
CP is in the wrong slot remove
and install CP into proper location.

4-41