AT&T System 25 User Manual
Page 213

MAINTENANCE
ERROR MESSAGE
AND DESCRIPTION
POSSIBLE SOLUTION
External Stack Full: (STARLAN
If the reset is not successful
Interface CP) This error resets the
reseat board. If the reseat fails,
C P .
replace the board.
F a u l t o n
Outgoing
Seizure:
Check trunk for slow dial tone;
ZTN76/TN747 CO ground was not
more than 10 seconds. Perform
detected within a predetermined
t r u n k test
c a l l
p e r “Trunk
time-frame.
ZTN77/747
loop
procedure in this
current was not detected within a
section. If the problem persists,
predetermined time frame.
Frame Length Error: (STAR LAN
Recoverable; no action required.
Interface CP) Packet length too
long for ZTN84.
.
Generator DSP Insane: Service
If a
“Generator DSP Sane”
Circuit problem.
occurred, the system will remove
this error from the permanent
alarm table.
If the problem
persists, check or replace the
faulty CP.
Generator DSP Sane:
Service Recoverable; no action required.
Circuit recovered from insane
condition.
Ground But No Ringing: T h e
Incoming calls are okay. The
switch does not detect ringing
problem could exist at the CO,
from the CO within 5 seconds of
bad ringing generator or a bad
Tip ground on an incoming ground
ring detector on the board. The
start call.
Tip lead could be getting ground
hits. Perform a trunk test call per
procedure in
this section.