Connection to ztn76 or ztn77 cp – AT&T System 25 User Manual
Page 157
INSTALLATION
Connection to ZTN76 or ZTN77 CP
PagePac 20 system with ZoneMate 9/39 and Common Control Unit (CCU)
provides up to nine/thirty-nine paging zones and multizone groups.
To connect a PagePac 20 system, make connections using the following
1.
2.
3.
4.
5.
6.
7.
Place the PagePac amplifier on the ZoneMate and the CCU.
Connect the three units as follows:
a .
Plug the cord attached to the CCU into the modular jack on
the PagePac system.
b. Connect the 25-pin cable between the ZoneMate and the
C C U .
c .
Plug GR Molex connector from CCU into PagePac 20.
Using a D4BU modular cord connect the jack on the back of the
CCU to the 103A connecting block.
Using 4-pair inside wiring cable, connect the 103A connecting block
to the TAE 700A block. Make the following connections:
700A Block Term.
103A Term.
T
1
R
2
Attach the speakers to the ZoneMate.
Set the switch on the CCU to LS for loop-start trunks or GS for
ground-start trunks.
For ground start trunks, connect the black lead from the 2-pair cord
supplied with PagePac 20 to the System 25 cabinet ground block.
2-128