beautypg.com

Table e-r, Port options, E-33 – AT&T System 25 User Manual

Page 352

background image

APPENDIX E: Administration Codes and Data

Table E-R.

Port Options

PORTS, Station/Trunk/Special Port Circuit Board Options

FOR QUALIFIED SYSTEMS TECHNICIANS ONLY

(See Table E-S, " Applicable Options " )

ACTION

DESCRIPTION

DATA

32

Set CO disconnect time (in 20 msec

[0-2540 msec; 500]

increments)

33

Set end-to-end signaling tone timing
(in 20 msec increments)
FOR TN742 AND ZTN78 ONLY:

[20-2540 msec; 340]

FOR ALL OTHER BOARDS:

[0-2540 msec; 60]

34

Set end-to-end signaling pause timing

(in 20 msec increments)

FOR TN742 AND ZTN78 ONLY:

[20-2540 msec; 100]

FOR ALL OTHER BOARDS:

[0-2540 msec; 60]

35

Set hybrid balance. Data is balance

[1/0] .

t y p e :

1=Resistor;

0=Resistor/Capacitor.

Trunk ports

default to 0; station ports default to 1.

36

Set gain; 1 (Gain=3dB) or 0 (Gain=0dB)

[ 1 / 0 ]

37

Set E&M signaling type. Data is

[ 0 - 2 ]

signaling type 0 (Type 1 compatible), 1
(Type V), or 2 (Type l).

38

Set answer supervision delay timing

[0-51 00 msec; 300]

Warning: The default values in Tables E-R and E-S must not be

changed without the support and guidance of Tier Ill
s t a f f .