Counter Reader
5
Device Manager
5-17
3
Check the results of counter Information.
–
Click the [Start] button to start acquiring counter information again
only for devices whose "Availability" column indicates "Time Out"
or "Error". Counter information is not collected for devices whose
"Availability" column indicates "Success" or "Uncollected".
Function
Details
Availability
Displays the results of the counter collection or the current
state of the counter collection.
Displays the following states.
• Success: The counter collection was successfully com-
pleted.
• Uncollected: No counter collection was performed.
• Waiting: Device is waiting for counter collection.
• Time Out: Failed to communicate with a device. Check
the device power or the settings on Device Information
Settings page for the Device List.
• Error (SNMP): An error occurred when collecting infor-
mation on counters. Check the SNMP settings for the
relevant device or the settings on Device Information
Settings page for the Device List.
• Error (HTTP): An error occurred when collecting informa-
tion on counters. Check the HTTP settings for the rele-
vant device or the settings on Device Information
Settings page for the Device List.
• Error (FTP): An error occurred when collecting informa-
tion on counters. Check the FTP settings for the relevant
device or the settings on Device Information Settings
page for the Device List.
• Error (Other): An error occurred when collecting informa-
tion on counters. Perform counter collection again. Or,
check the settings on the Device Information Settings
page for the Device List again.
Last Success Date
The last date and time at which counter collection was suc-
cessfully completed.
For a device on which no counter collection has been per-
formed or counter collection has never been successfully
completed, none will be listed.
Registered Name
Displays the registered name of the device.
Model Name