4. Commissioning
4−38
Festo P.BE−SPC200−COM−PDP−E N en 0901c
4.6.1 Internal I/O addresses with the Start/Stop mode
The configured outputs of the master are mapped on the
input bits.
Byte
Bit 7
Bit 15
Bit 6
Bit 14
Bit 5
Bit 13
Bit 4
Bit 12
Bit 3
Bit 11
Bit 2
Bit 10
Bit 1
Bit 9
Bit 0
Bit 8
Input bits (I10.0...I13.15)
1)
n
n + 1
I10.7
I10.15
I10.6
I10.14
I10.5
I10.13
Sync_IB
I10.12
Sync_IA
I10.11
STOP
I10.10
START/
RESET
I10.9
ENABLE
I10.8
n+2
n+3
I11.7
I11.15
I11.6
I11.14
I11.5
I11.13
I11.4
I11.12
I11.3
I11.11
I11.2
I11.10
I11.1
I11.9
I11.0
I11.8
n+4
n+5
I12.7
I12.15
I12.6
I12.14
I12.5
I12.13
I12.4
I12.12
I12.3
I12.11
I12.2
I12.10
I12.1
I12.9
I12.0
I12.8
n+6
n+7
I13.7
I13.15
I13.6
I13.14
I13.5
I13.13
I13.4
I13.12
I13.3
I13.11
I13.2
I13.10
I13.1
I13.9
I13.0
I13.8
1)
Address assignment from the point of view of the SPC200
The internal outputs of the field bus module are mapped on
the configured inputs of the master.
Byte
Bit 7
Bit 15
Bit 6
Bit 14
Bit 5
Bit 13
Bit 4
Bit 12
Bit 3
Bit 11
Bit 2
Bit 10
Bit 1
Bit 9
Bit 0
Bit 8
Output bits (Q10.0...Q13.15)
1)
n
n + 1
Q10.7
Q10.15
Q10.6
Q10.14
Q10.5
Q10.13
MC_B
Q10.12
MC_A
Q10.11
Sync_OB
Q10.10
Sync_OA
Q10.9
READY
Q10.8
n+2
n+3
Q11.7
Q11.15
Q11.6
Q11.14
Q11.5
Q11.13
Q11.4
Q11.12
Q11.3
Q11.11
Q11.2
Q11.10
Q11.1
Q11.9
Q11.0
Q11.8
n+4
n+5
Q12.7
Q12.15
Q12.6
Q12.14
Q12.5
Q12.13
Q12.4
Q12.12
Q12.3
Q12.11
Q12.2
Q12.10
Q12.1
Q12.9
Q12.0
Q12.8