4. Commissioning
4−32
Festo P.BE−SPC200−COM−PDP−E N en 0901c
GSD file (device master file)
Information on using the GSD file can be found in section 4.3.
In addition to slave−typical entries (Ident. number, Revision,
etc.), the device master file also contains a selection of identĆ
ifiers. These identifiers are divided into 4 main groups:
1. address range for digital inputs
2. address range for digital outputs
3. address range for the parameter channel
4. address range for actual positions
When configuring, observe the rules in section 4.4. If conĆ
figuration faults occur, make sure that the rules for configurĆ
ation are observed (see section 4.4.2).
Please note
Outputs of the master are mapped on internal inputs of the
field bus module; internal outputs of the field bus module
are mapped on inputs of the master.
Please note
Ĉ You must configure one identifier each for inputs and for
outputs.
Ĉ All internal outputs of the field bus module, which lie
outside the I/O address range configured for communiĆ
cation, can be used as flags in the Start/Stop operating
mode.