6. Diagnosis and error treatment
6−6
Festo P.BE−SPC200−COM−PDP−EN en 0901c
Status message
Meaning
Field bus type
Protocol of the installed field bus module
Connection
Parametrizing:
No connection to the field bus; the SPC200 waits for
parametrizing by the master
Configuring:
Waits for configuration by the PROFIBUS master
Data exchange:
Data exchange is running
Bus address
Set field bus address
Baud rate
Current baud rate of the PROFIBUS−DP network
1)
I/O assignment
Number of I/O bytes used for communication
2)
Software version
Software version number of the field bus module
Information
Information such as SYNC/FREEZE active, baud rate search or information on
faults (see Fig. 6/3)
1)
While the connection is being made, the display changes constantly until the SPC200 can
ascertain the baud rate of the PROFIBUS−DP network.
2)
The entry 0I/0O byte means that the master has not yet specified an I/O field size.
Fig. 6/2: Meaning of the status messages