4. Commissioning

4−6

Festo P.BE−SPC200−COM−PDP−E N en 0901c

Start/Stop mode

Address

1)

Control signal

Description

I10.0

ENABLE

Controller enable (1 = controller enabled)

2)

I10.1

START/RESET

Start/Continue or reset program (RESET in conjunction
with STOP = 0)

I10.2

STOP

Stop program sequence (0 = stopped)

I10.3/I10.4

SYNC_A/B

Synchronization input for M00

Q10.0

READY

System ready to operate

Q10.1/Q10.2

SYNC_OA/B

Synchronization output for M00

Q10.3/Q10.4

MC_A/B

MC output for program A/B (motion complete)

1)

Address assignment from the point of view of the SPC200

2)

Observe the instructions on enabling the controller in section4.1.

Record Select mode

Address

1)

Control signal

Description

I10.0

ENABLE

Controller enable (1 = controller enabled)

2)

I10.1

RESET

Reset program (in conjunction with STOP = 0)

I10.2

STOP

Stop positioning task (0 = stopped)

I10.3/I10.4

CLK_A/B

Start NC record from program A/B

I11.0 ... I11.9

RECBIT1...10

Bits for NC record number (RECBIT1 for 2

0

etc. )

Q10.0

READY

System ready to operate

Q10.1/Q10.2

ACK_A/B

Task accepted for program A/B

Q10.3/Q10.4

RC_A/B

NC record concluded by program A/B

1)

Address assignment from the point of view of the SPC200

2)

Observe the instructions on enabling the controller in section4.1.