5. Parameter channel

5−13

Festo P.BE−SPC200−COM−PDP−E N en 0901c

PNU 204

d

(CC

h

): Diagnostic event

Description

Fault messages of the SPC200
The fault message is to be interpreted as an eight−figure hexadecimal number.

Permitted values

0000.0000...FFFF.FFFF

Presetting

0

Data type

Unsigned32

Unit

Ĉ

Subindices

1: Current diagnostic event n (current fault message)
2: Diagnostic event in the diagnostic memory

1)

n−1

3: Diagnostic event in the diagnostic memory

1)

n−2

4: Diagnostic event in the diagnostic memory

1)

n−3

...
17: Diagnostic event in the diagnostic memory

1)

n−16

Access rights

Read: yes; write: no

Protected against
power failure

No

Task identifier

6, 9

Reply identifier
(positive)

5, 6

Reference

Descriptions of the eight−figure hexadecimal fault messages see System
Manual

1)

The diagnostic memory (fault stack) serves for protocolling fault states. By recording fault
sequences, you can find the cause of faults which are otherwise difficult to locate. If the causes
are eliminated, faults can be avoided over long periods.