4. Commissioning
4−17
Festo P.BE−SPC200−COM−PDP−E N en 0901c
4.4.3 DP identifiers for the I/O signals
Please note
Output addresses of the master are mapped on internal
inputs; internal outputs of the field bus module are
mapped on input addresses of the master.
DP identifiers for the Start/Stop mode
In the Start/Stop mode identifiers for data consistency over
1Ăbyte are permitted.
I/O signals
Address range
DP identifiers
EN 50170
Siemens
EN 50170
Siemens
Consistent over
1 byte
Complete length
Q10.0...Q10.15
Q11.0...Q11.15
Q12.0...Q12.15
Q13.0...Q13.15
2 I−bytes
+2 I−bytes (4 I−bytes)
+2 I−bytes (6 I−bytes)
+2 I−bytes (8 I−bytes)
11
h
13
h
15
h
17
h
16DI
32DI
21
d
23
d
91
h
93
h
95
h
97
h
145
d
147
d
149
d
151
d
Fig. 4/5: DP identifiers for inputs (outputs of the SPC200)
I/O signals
Address range
DP identifiers
EN 50170
Siemens
EN 50170
Siemens
Consistent over
1 byte
Complete length
I10.0...I10.15
I11.0...I11.15
I12.0...I12.15
I13.0...I13.15
2 O−bytes
+ 2 O−bytes (4 O−bytes)
+ 2 O−bytes (6 O−bytes)
+ 2 O−bytes (8 O−bytes)
21
h
23
h
25
h
27
h
16DO
32DO
37
d
39
d
A1
h
A3
h
A5
h
A7
h
161
d
163
d
165
d
167
d
Fig. 4/6: DP identifiers for outputs (inputs of the SPC200)