4. Commissioning

4−28

Festo P.BE−SPC200−COM−PDP−E N en 0901c

Bit

Explanation

Meaning

5

Sync_Req

log. 1": Activate SYNC

6
7

Unlock_Req
Lock_Req

Bit 7

Bit 6

0

0

0

1

1

0

1

1

min T

SDR

+ SPC200 parameters may be

overwritten

SPC200 released for other masters

SPC200 blocked for other masters

SPC200 released for other masters

Bytes 2 and 3:

WD_Fact_1
WD_Fact_2

Bit

Meaning

Explanation

Range 1...255:
The response monitoring time of the SPC200 is transmitted with these two
bytes: T

WD

[s] = 10ms * WD_Fact_1 * WD_Fact_2

Byte 4: Minimum station delay responder (min T

SDR

)

Bit

Meaning

Explanation

The minimum time the SPC200 must wait, before the reply telegram may
be sent to the DP master.

Bytes 5 and 6: Ident_number

Bit

Meaning

Explanation

Transmission of the Ident number (= 00C8

H

) of the SPC200.

Parametrizing telegrams to the SPC200 are only accepted if the
transmitted and the programmed Ident numbers are the same.