Station status 2 (only SPC200−related bits)

Station status 2

Bit

Meaning

Explanation

0

Diag.Prm_Req

1 = Master must configure the SPC200 again

1

Diag.Stat_Diag

1 = Master must request diagnostic data until this bit is

set to 0

2

Ĉ

Always 1 (set to logical 1 by the SPC200)

3

Diag.WD_On

1 = Response monitoring/watchdog activated

4

Diag.Freeze_Mode

1 = Freeze activated

1)

5

Diag.Sync_Mode

1 = Sync activated

1)

6

Ĉ

Reserved

7

Diag.Deactivated

Always 0 (always reset to 0 by the SPC200)

1)

Only in conjunction with a diagnostic message

Fig. 6/5: Diagnostic bits of station status 2

Station status_3

Bit

Meaning

Explanation

0...6

Ĉ

Reserved

7

Diag.Ext_Diag_Overflow

Is always logical 0 (set by the SPC200)

Fig. 6/6: Diagnostic bits of station status_3