6. Diagnosis and error treatment
6−10
Festo P.BE−SPC200−COM−PDP−EN en 0901c
Station status 2 (only SPC200−related bits)
Station status 2
Bit
Meaning
Explanation
0
Diag.Prm_Req
1 = Master must configure the SPC200 again
1
Diag.Stat_Diag
1 = Master must request diagnostic data until this bit is
set to 0
2
Ĉ
Always 1 (set to logical 1 by the SPC200)
3
Diag.WD_On
1 = Response monitoring/watchdog activated
4
Diag.Freeze_Mode
1 = Freeze activated
1)
5
Diag.Sync_Mode
1 = Sync activated
1)
6
Ĉ
Reserved
7
Diag.Deactivated
Always 0 (always reset to 0 by the SPC200)
1)
Only in conjunction with a diagnostic message
Fig. 6/5: Diagnostic bits of station status 2
Station status_3
Bit
Meaning
Explanation
0...6
Ĉ
Reserved
7
Diag.Ext_Diag_Overflow
Is always logical 0 (set by the SPC200)
Fig. 6/6: Diagnostic bits of station status_3