5. Parameter channel

5−12

Festo P.BE−SPC200−COM−PDP−E N en 0901c

PNU 200

d

... 201

d

(C8

h

... C9

h)

PNU 200

d

(C8

h

)

Actual position

PNU 201

d

(C9

h

)

Nominal position

Description

Current actual position of the axis

Current nominal position of the axis

1)

Permitted values

−99,999,900 ... +99,999,900 (

Z −9,999.99 ... +9,999.99 mm)

Presetting

Actual position of the axis

500,000 (

Z 50,0000 mm)

Data type

Integer32 (see section A.1.5)

Unit

0.1 Ģm (= 0.0001 mm)

Subindices

1: X−axis
2: Y−axis
3: Z−axis
4: U−axis

Access rights

Read: yes; write: no

Read: yes; write: no

Protected against
power failure

Ĉ

Ĉ

Task identifier

6, 9

6, 9

Reply identifier
(positive)

5, 6

5, 6

1)

The current actual position of the controller is important for relative nominal value specifications.
A relative nominal value specification always refers to the last nominal position communicated to
the controller.

PNU 202

d

... 203

d

(CA

h

... CB

h)

PNU 202

d

(CA

h

)

reserved

PNU 203

d

(CB

h

)

reserved

Description

Reserved for later extensions