beautypg.com

Festo Кабели и принадлежности User Manual

Page 57

background image

4. Commissioning

4−11

Festo P.BE−SPC200−COM−PDP−E N en 0901c

1

1

Register card Field bus"

Fig. 4/4: Configuration of the field bus module

4. Set the following in this register card:

Settings

Notes

PROFIBUS address

Fieldbus addresses may only be assigned once per PROFIBUS−DP interface
(0 ... 125)

Suppress diagnostic
messages

As from firmware version V2.1 of the fieldbus module:
Error messages over the fieldbus can be suppressed with WinPISA as from
version 4.51 in combination with an operating system as from version 4.93.
This avoids an undesired stop of the PLC.

Recommendation: Assign the PROFIBUS addresses in ascendĆ
ing order. If necessary, assign the PROFIBUS addresses to
suit the machine structure of your system.

5. Confirm the settings with OK.

The field bus address set will be transmitted to the SPC200
when the project is loaded and will then become valid. A sepĆ
arate download is also possible.

This manual is related to the following products: