HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 87
Command line 87
Item
Description
added. The server profile can be assigned to a device bay using the "assign"
subcommand.
Profiles are created without FCoE connections if the QoS type is set to
"CustomNoFcoe". For more information about setting the QoS type, see "qos (on
)."
Syntax
add profile
[-NoDefaultFcConn] [-NoDefaultFcoeConn] [Nag=
[HideUnusedFlexNICs=
[SNType=
[SerialNumber=
Parameter
ProfileName
The unique name of the new server profile to create
Options
NoDefaultEnetConn
Do not add default Ethernet network connections when creating the server profile.
NoDefaultFcConn
Do not add default FC SAN connections when creating the server profile.
NoDefaultFcoeConn
Do not add default FCoE SAN connections when creating the server profile.
Properties
Nag (optional)
Network access group for the profile. The default is the domain default network
access group.
HideUnusedFlexNICs
(optional)
When set to "false," all physical functions of the FlexNICs are enumerated in the
operating system as network interfaces. This includes FlexNICs not mapped to
profile connections. Enumerating unmapped network interfaces might consume
shared resources, even though the interfaces are unused. The default is "true."
SNType (optional)
The source of the serial number assignment used during the profile creation. If not
specified, the serial number is assigned according to the VC default domain
settings. Values include "Factory-Default", "User-Defined", and "Pool-Specified".
To use the "Pool-Specified" option, the domain level pool must be set to VC-Defined
or User-Defined. Any "Pool-Specified" serial number must come from the currently
selected VC-defined or user-defined serial number pool.
SerialNumber
(required if the
SNType is
User-Defined or
Pool-Specified)
A custom user-defined serial number associated with the server profile. When the
profile is assigned to a device bay containing a server, the server inherits the virtual
serial number. The user-defined serial number must start with the pattern VCX01.
UUID (optional)
A unique 128-bit identifier for the virtual server ID. The format is
xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx, where x is any alphanumeric character. If
no UUID is specified, one is auto-generated. The UUID can be specified only if the
SNType is "User-Defined".
Examples
->add profile MyNewProfile
Creates a new profile and adds it to the domain, using default connections and VC
default serial numbers
->add profile MyNewProfile2 -NoDefaultEnetConn
Creates a new profile without adding default Ethernet connections
->add profile MyNewProfile2 -NoDefaultFcConn
Creates a new profile without adding default FC connections
->add profile MyNewProfile2 -NoDefaultFcoeConn
Creates a new profile without adding default FCoE connections
->add profile MyNewProfile2 -NoDefaultEnetConn
-NoDefaultFcConn
Creates a new profile without adding default Ethernet and FC connections
->add profile MyNewProfile2 -NoDefaultEnetConn
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem