beautypg.com

HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 44

background image

Command line 44

Item

Description

Syntax

set fc-connection

[Fabric=]

[Speed=]

[BootPriority=] [BootPort=]

[BootLun=]

Parameters

ProfileName (required) The name of the server profile containing the connection to modify
Port (required)

The port number of the connection being modified

Properties

Fabric (optional)

The name of the FC SAN fabric associated with the connection. Associate the

specified fabric with the same bay as the FC connection. A blank string makes
the FC connection unassigned.

Speed (optional)

The port speed of the FC SAN connection. Values include "Auto", "8Gb",

"4Gb", "2Gb", "1Gb", and "Disabled".

Speed restrictions:
For the HP VC 4Gb FC Module, supported speed values include

"Auto","1Gb","2Gb", "4Gb", and "Disabled". If the value is set to 8Gb, the

speed is auto-negotiated by VC.

BootPriority

(optional)

Controls whether the FC HBA port is enabled for SAN boot and affects the BIOS
boot order. Values include "BIOS", "Primary", "Secondary", and "Disabled".

BootPort

(Required if the Boot Priority is

either Primary or Secondary,
otherwise optional)

The target WWPN of the controller interface on the Fibre Channel storage

target. The port name is a 64-bit identifier in the format

NN:NN:NN:NN:NN:NN:NN:NN, where N is a hexadecimal number.

BootLun

(Required if the Boot Priority is

either Primary or Secondary,

otherwise optional)

The LUN of the volume used for SAN boot. Values include integers from 0 to
255 or 16 hex digits (HP-UX only).

Examples

->set fc-connection MyProfile 1 Fabric=SAN_5

Changes the fabric of an FC SAN fabric connection

->set fc-connection RedProfile 2 Fabric=""

Sets an FC SAN fabric connection to "Unassigned"

->set fc-connection BlueProfile 1 Fabric=SAN_7

Changes the FC SAN fabric of an FC SAN connection

->set fc-connection BlueProfile 1 Speed=4Gb

Changes the port speed of an FC SAN connection

->set fc-connection BlueProfile 1 BootPriority=Primary

BootPort=50:06:0B:00:00:C2:62:00 BootLun=5

Changes the SAN boot priority and sets additional boot parameters

Item

Description

show fc-connection

Display the FC SAN connections associated with the server profiles.

Syntax

show fc-connection []

Parameter