Network – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 78
Command line 78
Item
Description
PrefSpeed (required if
PrefSpeedType is "Custom")
The connection speed for any Ethernet connection attached to these
networks. Valid values range from 100Mb to the MAX configured speed
for the network in 100Mb increments.
MaxSpeedType (Optional)
The maximum connection speed for any Ethernet connection attached to
these networks. Valid values include "Unrestricted" and "Custom".
"Custom" enables you to configure the preferred speed. The default value
is "Unrestricted".
MaxSpeed (required if
MaxSpeedType is "Custom")
The maximum connection speed for any Ethernet connection attached to
these networks. Valid values range from 100Mb to the MAX configured
speed for the network in 100Mb increments.
Nags (optional)
The network access groups to which the networks belong, separated by
commas. Do not use spaces unless they are enclosed in quotation marks.
If nags is not specified, the network access groups are not changed.
SmartLink (optional)
Enables or disables the SmartLink capability for the networks. Valid values
include "Enabled" and "Disabled".
Labels (optional)
Labels assigned to these networks. Labels are used in the GUI to help with
management of large numbers of networks. Labels can be assigned in the
CLI, but are only used in the GUI. A maximum of 16 labels can be
assigned.
Color (optional)
Color assigned to these networks. Color is used in the GUI to manage
large numbers of networks. A color can be assigned in the CLI, but is only
used in the GUI. Red, green, blue, purple, or orange are allowed.
Example
->set network-range UplinkSet=Alpha
VLANIDs=1-10,21-30 SmartLink=Enabled
Changes the SmartLink setting for multiple networks
network
Manage Virtual Connect Ethernet networks.
Supported actions: add, help, remove, set, show
Item
Description
add network
Create a new Ethernet or FCoE network. An FCoE network is associated to an uplink
port set. After the network is created, uplink ports can be added if the network is not
using a shared uplink set.
The SmartLink property is no longer supported during the creation of the network. If
specified, it is ignored. To configure the SmartLink attribute, use the set network
command.
If the QoS type is set to "CustomNoFcoe", a "cannot add fabric when QoS
configuration type is CustomNoFCoE" error message appears. For more information
about setting the QoS type, see "qos (on page
)."
Syntax
add network
[Nags=
VLanID=
[NativeVLAN=
[ConnectionMode=
[VLanTunnel=
[PrefSpeed=<100Mb–20Gb in 100Mb increments]
[MaxSpeedType=
100Mb increments>]
[LacpTimer=
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem