Uplinkport – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 132
Command line 132
Item
Description
Tests the TACACS+ configuration changes without applying them
->set tacacs Enabled=true ServerAddress=192.168.0.124
ServerKey=test123 SecondaryServerAddress=tacserver.hp.com
SecondaryServerKey=test456
->set tacacs Enabled=true ServerAddress=2001::70
ServerKey=test123 SecondaryServerAddress=tacserver.hp.com
SecondaryServerKey=test456
Enables TACACS+ authentication for users
->set tacacs LoggingEnabled=true
Enables TACACS server logging
Item
Description
show tacacs
Display the Virtual Connect TACACS+ authentication settings.
Syntax
show tacacs
Example
->show tacacs
Displays TACACS+ information
uplinkport
Manage interconnect module uplink ports.
Supported actions: add, help, remove, set, show
Item
Description
add uplinkport
Add a new uplink port to an existing network or a shared uplink port set.
Syntax
add uplinkport
UplinkSet=
[Speed=
[Role=
Parameter
PortID (required) The ID of an uplink port to add. The ID is a combination of the enclosure name,
interconnect bay, and port number in a single descriptor. The port ID for a network or
an uplinkset that does not contain an FCoE network uses the format
For QSFP+ ports, the
If the uplinkset contains an FCoE network, then the port is configured for all enclosures.
The port name is in the format
Properties
Network
(required)
The name of an existing network to which the port is added if the shared uplink set
name is not specified
UplinkSet
(required)
The name of an existing shared uplink set to which the port is added if the network
name is not specified
Speed (optional) Specifies the port speed for the port (optional). Depending on the VC module, valid
values are "Auto", "10Mb", "100Mb", "1Gb", "10Gb", "40Gb", and "Disabled".
If not specified, the default port speed is "Auto". If no connector is present on the uplink
port, only "Auto" and "Disabled" can be configured as the speed. Speed restrictions
apply.
Role (optional)
The role played by the port if the connection mode of the network or shared uplink set
is selected as "Failover". Valid values are "Primary" and "Secondary". The default
value is "Primary". If the uplink set contains an FCoE network, then the Role property is
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem