Virtual connect overview – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 10
Introduction 10
# Add uplink ports to the networks
add uplinkport enc0:1:1 network=MyNetwork
add uplinkport enc0:1:2 network=Network2
# Create a Shared Uplink Port Set
add uplinkset SharedSet1
# Add a new FCoE SAN fabric connection to a profile
add fcoe-connection MyNewProfile Fabric=SAN_5
# Reset the active QoS configuration type to the factory default settings but
does not change the saved configuration types
reset qos -active
# Set the domain default LACP timer to the short setting (one second)
set lacp-timer default=Short
# Add a Multicast Filter "filter1" to Filterset "mfs1"
add mfs-filter FilterSet=mfs1 McastFilter =filter1
# Set the global option to enable the loop protection and pause flood protection
set port-protect networkLoop=Enabled PauseFlood=Enabled
# Set idle user sessions to expire after 20 minutes of inactivity
set session Timeout=20
# Create a new Multicast Filter and adds it to the domain
add mcast-filter MyMcastFilter
# Assign a profile to a device bay
assign profile MyProfile enc0:1
# Done!!!
Virtual Connect overview
HP Virtual Connect is a set of interconnect modules and embedded software for HP BladeSystem c-Class
enclosures. VC simplifies the setup and administration of server connections and includes the following
components:
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem