beautypg.com

Iscsi-boot-param – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 52

background image

Command line 52

Item

Description

UplinkSet=up1 LAG=18'.

Option

fip_snooping

Display FIP snooping information for the specified interconnect module.

Examples

->show interconnect

Displays a summary of all interconnect modules

->show interconnect *

Displays detailed information for all interconnect modules

->show interconnect *:5

Displays detailed information for all enclosures with interconnect modules in

interconnect bay number 5

->show interconnect enc0:*

Displays interconnect modules in all bays of a specific enclosure

->show interconnect enc0:3

Displays detailed information on a specific interconnect module in interconnect

bay 3 of the primary enclosure

->show interconnect enc0:3 -fip_snooping

Displays FIP snooping information on a specific interconnect module in

interconnect bay 3 of the primary enclosure

iscsi-boot-param

Manage iSCSI boot parameters within a domain.

NOTE:

The iscsi-boot-param command does not currently support IPv6 addresses.


Supported actions: help, remove, set, show

Item

Description

remove

iscsi-boot-param

Remove all iSCSI boot parameters configured on the specified iSCSI

connection.

Syntax

remove iscsi-boot-param

Parameter

ConnectionID

(required)

The ID of an existing iSCSI connection. The ID format is . To
retrieve the port number of the iSCSI connection, use the show profile

command.

Example

->remove iscsi-boot-param MyProfile1:1

Removes boot parameters configured on connection 1 of MyProfile1

Item

Description

set iscsi-boot-param

Configure the basic iSCSI boot parameters on the specified iSCSI connection.

Syntax

set iscsi-boot-param [-maskSecret]

[-maskMutualSecret]

[BootOrder=]

[LUN=] [InitiatorName=

name>] [InitiatorIP=] [Mask=]

[Gateway=] [VlanID=]

[TargetName=] [TargetIP=]