Flexfabric fc uplink ports – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 158
Command line 158
Name
RFC
Description
rfc2665_Dot3StatsLate
Collisions
2665
The number of times that a collision is detected on a particular interface
later than one slotTime into the transmission of a packet. A late collision
included in a count represented by an instance of this object is also
considered a generic collision for purposes of other collision-related
statistics. This counter does not increment when the interface is
operating in full-duplex mode. Discontinuities in the value of this counter
can occur at reinitialization of the management system and at other
times as indicated by the value of ifCounterDiscontinuityTime.
rfc2665_Dot3StatsSQE
TestErrors
2665
The number of times that the SQE TEST ERROR message is generated by
the PLS sublayer for a particular interface. The SQE TEST ERROR is set
in accordance with the rules for verification of the SQE detection
mechanism in the PLS Carrier Sense Function as described in IEEE Std.
802.3, 1998 Edition, section 7.2.4.6. This counter does not increment
on interfaces operating at speeds greater than 10 Mb/s, or on
interfaces operating in full-duplex mode. Discontinuities in the value of
this counter can occur at reinitialization of the management system and
at other times as indicated by the value of ifCounterDiscontinuityTime.
The object type is dot3StatsSQETestErrors.
rfc2665_Dot3StatsSingle
CollisionFrames
2665
The number of successfully transmitted frames on a particular interface
for which transmission is inhibited by exactly one collision. A frame that
is counted by an instance of this object is also counted by the
corresponding instance of either ifOutUcastPkts, ifOutMulticastPkts, or
ifOutBroadcastPkts, and is not counted by the corresponding instance
of the dot3StatsMultipleCollisionFrames object. This counter does not
increment when the interface is operating in full-duplex mode.
Discontinuities in the value of this counter can occur at reinitialization of
the management system and at other times as indicated by the value of
ifCounterDiscontinuityTime.
rfc2665_Dot3StatsSymbol
Errors
2665
For an interface operating at 100 Mb/s, the number of times there was
an invalid data symbol when a valid carrier was present.
For an interface operating in half-duplex mode at 1000 Mb/s, the
number of times the receiving media is non-idle (a carrier event) for a
period of time equal to or greater than slotTime, and during which there
was at least one occurrence of an event that caused the PHY to indicate
'Data reception error' or 'carrier extend error' on the GMII.
For an interface operating in full-duplex mode at 1000 Mb/s, the
number of times the receiving media is non-idle (a carrier event) for a
period of time equal to or greater than minFrameSize, and during
which there was at least one occurrence of an event that caused the
PHY to indicate 'Data reception error' on the GMII. The count
represented by an instance of this object is incremented once per
carrier event at most, even if multiple symbol errors occur during the
carrier event. This count does not increment if a collision is present.
Discontinuities in the value of this counter can occur at reinitialization of
the management system and at other times as indicated by the value of
ifCounterDiscontinuityTime.
FlexFabric FC uplink ports
Name
RFC
Description
fcAddressErrors
4044
The number of frames received with unknown addressing, such as an
unknown SID or DID. The object type is fcmPortAddressErrors.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem