MaxHeaderSize
(optional)
Specifies the maximum number of bytes that are copied from a sampled packet
to create a flow sample. Valid values are "128","256","512", and "1024".
The default value is "128".
MaxDatagramSize
(optional)
Specifies the maximum number of data bytes that are sent in a single datagram.
The valid range is from 256 to 1500. The default value is "1400".
The MaxDatagramSize must be greater than or equal to the
MaxHeaderSize plus 128 bytes of fixed header of an sflow datagram.
Examples
->add sflow-receiver Alpha ipaddress=10.10.2.22 port=6343
maxheadersize=256 maxdatagramsize=1400
Adds the Alpha sflow receiver
Item
Description
remove sflow-receiver
Remove a receiver.
Syntax
remove sflow-receiver
Parameter
ReceiverName (required) The name of an existing sflow receiver in the domain. A receiver name of "*"
removes all the receivers.
Example
->remove sflow-receiver Alpha
Removes the Alpha sflow receiver
->remove sflow-receiver *
Removes all sflow receivers
Item
Description
set sflow-receiver
Modify the receiver.
Syntax
set sflow-receiver >][Port= <1-65535>][MaxHeaderSize=<128|256|512|1024>] [MaxDatagramSize=<256-1500>][Enabled= Parameters ReceiverName (required) The name of an existing sflow receiver in the domain Properties IpAddress (optional) Specifies the IP Address of the receiver where the sflow datagrams are sent. Port (optional) Specifies the UDP port number of the receiver where the sflow datagrams are sent. The valid range is from 1 to 65535. The default value is "6343". MaxHeaderSize (optional) Specifies the maximum number of bytes that are copied from a sampled packet to create a flow sample. Valid values are "128","256","512", and "1024". MaxDatagramSize (optional) Specifies the maximum number of data bytes that are sent in a single datagram. The valid range is from 256 to 1500. The default value is "1400". MaxHeaderSize plus 128 bytes of fixed header of an sflow datagram. Enabled (optional) Enables or disables the sFlow receiver. Valid values are "true" and "false". The default value is "true". Examples ->set sflow-receiver Alpha enabled=true Enables the Alpha sflow receiver
The default value is "128".
The MaxDatagramSize must be greater than or equal to the
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem