Fcoe-connection – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 45
Command line 45
Item
Description
ConnectionID
(optional)
The ID of an existing FC SAN connection. The ID format is
Use
display all FC SAN connections in the domain.
Examples
->show fc-connection
Displays all FC SAN connections in the domain
->show fc-connection Profile1:*
Displays all FC SAN connections of a profile named Profile1
->show fc-connection Profile1:1
Displays a specific FC SAN connection of a profile named Profile1
fcoe-connection
Manage FCoE connections.
Supported actions: add, help, remove, set, show
Item
Description
add fcoe-connection
Add a new FCoE connection to an existing server profile. For more information,
see "General requirements for adding FC or FCoE connections (on page
)."
If the QoS type for the domain is set to "CustomNoFcoe", a "cannot add fabric
when QoS configuration type is CustomNoFCoE" error message appears. For
more information about setting the QoS type, see "qos (on page
)."
Syntax
add fcoe-connection
[Fabric=
[SpeedType=<1Gb|2Gb|4Gb|8Gb|Auto|Custom|Preferred|Disabl
ed>] [CustomSpeed=<100Mb-8Gb|20Gb>]
[WWNAddressType= fied>] [PortWWN= [MACAddressType= fied>] [EthernetMac= Parameter ProfileName (required) The name of an existing profile to which the new connection is added Fabric (optional) The name of an existing fabric created on an FCoE module to associate with the connection. If the fabric name is not specified, the connection is marked as FcoeNetwork (optional) The name of an existing FCoE network to associate with the connection. You cannot specify both Fabric and FcoeNetwork properties. If neither property is specified, then the connection is marked as "Unassigned" and is associated SpeedType (optional) The requested operation speed for the server port. Valid values are "1Gb", "2Gb", "4Gb", "8Gb", "Auto", "Custom", "Preferred", and "Disabled". The default value is "Preferred". "Auto" does not apply to fabrics, and "1Gb" to If the SpeedType is "Custom", you can configure a speed from 100Mb to MAX configured speed for the network in 100Mb increments. the preferred speed of the fabric or FCoE network to which the connection is associated. If no preferred speed is configured for a fabric or FCoE network, CustomSpeed (required The user-defined speed for the server port. Valid values include 100Mb to
Properties
“Unassigned” and associated with a specific bay.
with a specific bay.
"8Gb" does not apply to FCoE networks.
If the speed type is "Preferred", the speed of the FCoE connection is the same as
Virtual Connect determines the speed.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem