beautypg.com

Fcoe-connection – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 45

background image

Command line 45

Item

Description

ConnectionID

(optional)

The ID of an existing FC SAN connection. The ID format is .

Use to display all FC SAN connections of a profile. Use "*" to

display all FC SAN connections in the domain.

Examples

->show fc-connection

Displays all FC SAN connections in the domain

->show fc-connection Profile1:*

Displays all FC SAN connections of a profile named Profile1

->show fc-connection Profile1:1

Displays a specific FC SAN connection of a profile named Profile1

fcoe-connection

Manage FCoE connections.
Supported actions: add, help, remove, set, show

Item

Description

add fcoe-connection

Add a new FCoE connection to an existing server profile. For more information,

see "General requirements for adding FC or FCoE connections (on page

191

)."

If the QoS type for the domain is set to "CustomNoFcoe", a "cannot add fabric
when QoS configuration type is CustomNoFCoE" error message appears. For

more information about setting the QoS type, see "qos (on page

95

)."

Syntax

add fcoe-connection

[Fabric=|FcoeNetwork=]

[SpeedType=<1Gb|2Gb|4Gb|8Gb|Auto|Custom|Preferred|Disabl

ed>] [CustomSpeed=<100Mb-8Gb|20Gb>]

[WWNAddressType=

fied>] [PortWWN=] [NodeWWN=]

[MACAddressType=

fied>] [EthernetMac=]

Parameter

ProfileName (required) The name of an existing profile to which the new connection is added
Properties

Fabric (optional)

The name of an existing fabric created on an FCoE module to associate with the

connection. If the fabric name is not specified, the connection is marked as
“Unassigned” and associated with a specific bay.

FcoeNetwork (optional) The name of an existing FCoE network to associate with the connection.

You cannot specify both Fabric and FcoeNetwork properties. If neither property

is specified, then the connection is marked as "Unassigned" and is associated
with a specific bay.

SpeedType (optional)

The requested operation speed for the server port. Valid values are "1Gb",

"2Gb", "4Gb", "8Gb", "Auto", "Custom", "Preferred", and "Disabled". The

default value is "Preferred". "Auto" does not apply to fabrics, and "1Gb" to
"8Gb" does not apply to FCoE networks.

If the SpeedType is "Custom", you can configure a speed from 100Mb to MAX

configured speed for the network in 100Mb increments.
If the speed type is "Preferred", the speed of the FCoE connection is the same as

the preferred speed of the fabric or FCoE network to which the connection is

associated. If no preferred speed is configured for a fabric or FCoE network,
Virtual Connect determines the speed.

CustomSpeed (required The user-defined speed for the server port. Valid values include 100Mb to