beautypg.com

Fabric – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 39

background image

Command line 39

fabric

Manage Fibre Channel SAN fabrics.
Supported actions: add, help, remove, set, show

Item

Description

add fabric

Add a new fabric to the domain. If the QoS type for the domain is set to
"CustomNoFcoe", then the fabric cannot include FCoE ports. If it does, the message

"cannot add fabric when QoS configuration type is CustomNoFCoE" appears. For

more information about setting the QoS type, see "qos (on page

95

)."

Syntax

add fabric Bay= Ports=

[Type=] [Speed=]

[LinkDist=][PrefSpeedType=]

[PrefSpeed=<100Mb-8Gb in 100Mb

steps>][MaxSpeedType=]

[MaxSpeed=<100Mb-8Gb in 100Mb steps>]

Parameter

Name (required)

A unique name is required when new fabric is added to the domain.

Properties

Bay (required)

The specific interconnect bay number with which the fabric is associated.

Ports (required) A list of one or more logical FC ports to be added to the fabric.

Each port is specified in the format ",,...", where "port" is the

interconnect module port number to be added to the fabric, for example "1, 2, 3, 4"
(affects all modules within a bay group).

For HP VC FlexFabric 10Gb/24-port Modules, port numbers 1, 2, 3, and 4

correspond to ports X1, X2, X3, and X4, respectively.

For HP VC FlexFabric-20/40 F8 Modules, port numbers 1, 2, 3, 4, 5, 6, 7, and 8

correspond to ports X1, X2, X3, X4, X5, X6, X7, and X8, respectively. Ports X1

through X4 support Ethernet and Fibre Channel traffic. Port pairs X5/X6 and

X7/X8 carry a single type of network traffic, either Ethernet or Fibre Channel.

Type (optional)

The fabric type. "FabricAttach" is a SAN fabric. A "DirectAttach" fabric is directly
connected to a supported storage device. A "DirectAttach" fabric is only allowed for a

FlexFabric module. The default type is "FabricAttach".

Speed (optional) The port speed for the uplink ports in the fabric. Values include "Auto", "2Gb", "4Gb",

and "8Gb". The default port speed is "Auto".
Speed restrictions:

For the HP VC 4Gb FC Module, if the value is 8Gb, VCM translates the value to
"Auto", allowing the module to connect to the SAN switch at optimal speed.

For the HP VC 8Gb 24-Port FC Module, HP VC 8Gb 20-Port FC Module, HP VC

FlexFabric 10Gb/24-port Module, and HP VC FlexFabric 20/40 F8 module,

values include "Auto", "2Gb", "4Gb", and "8Gb".

LinkDist

(optional)

The login re-distribution scheme to use for load balancing. Values include "Auto" and
"Manual". The default login re-distribution is "Manual" for a "FabricAttach" fabric.

Login re-distribution is not supported for "DirectAttach" fabrics.

The HP VC 4Gb FC Module, HP VC 8Gb 20-Port FC Module, and HP VC 8Gb 24-Port
Module support only manual login redistribution. The HP VC FlexFabric 10Gb/24-port

Module and HP VC FlexFabric 20/40 F8 Module support both auto and manual login

redistribution.

PrefSpeedType

(optional)

Preferred connection speed for any FCoE connection attached to this fabric. Values are
"Auto" and "Custom". "Custom" allows configuration of the preferred speed. The

default value is "Auto" and can be configured only if the fabric has uplink ports from

the FlexFabric interconnect module.