Snmp-trap – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 115
Command line 115
snmp-trap
Manage SNMP trap information.
Supported actions: add, help, remove, set, show, test
Item
Description
add snmp-trap
Adds a new SNMP trap destination.
You can configure up to five VC-Enet and five VC-FC SNMP trap destinations.
Avoid using duplicate trap destinations. Setting duplicate trap destinations can
result in duplicate traps being sent to the same destination, or only one of the trap
destinations being configured.
Syntax
add snmp-trap
[Community= string>][Format= severity|All|None>][DomainCategories= category|All|None>][EnetCategories= category|All|None>][FcCategories= category|All|None>] Parameter Name (required) A unique name for the new trap being added Properties Address (required) IP address or DNS name for the trap destination value is "public". For VC-Enet modules, the maximum string length is 39. For VC-FC Format Format of the new trap. Values are "SNMPv1" and "SNMPv2". If not specified, the default is "SNMPv1". Severities Trap severities to send to the destination. Values are "Normal", "Unknown", "Info", can be specified, separated by commas. The default severity is "None". DomainCategories The VC domain trap categories to send to the destination. Values are "Legacy", "DomainStatus", "NetworkStatus", "FabricStatus", "ProfileStatus", "ServerStatus", separated by commas. EnetCategories The VC Ethernet trap categories to send to the destination. Values are "PortStatus", separated by commas. FcCategories The VC Fibre Channel trap categories to send to the destination. Values are "PortStatus", "Other", "All", and "None". Multiple categories can be specified, Examples ->add snmp-trap EnetManagementStation Address=192.112.34.10 Community=private Format=SNMPv1 Severity=Normal,Critical EnetCategories=Other Adds a new trap destination for VC-Enet modules ->add snmp-trap FcManagementStation Address=192.112.72.3 Community=private Format=SNMPv1 FcCategories=Other Adds a new trap destination for VC-FC modules ->add snmp-trap MyTrap Address=192.112.66.12 Adds a new trap using typical defaults ->add snmp-trap MyTrap Address=2001:05c0:9168::1 Severity=All EnetCategories=All Adds a new trap destination using an IPv6 address
Community (optional) The SNMP community name string for the specified trap. If not specified, the default
modules, the maximum string length is 24.
"Warning", "Minor", "Major", "Critical", "All", and "None". Multiple severities
"EnetStatus", FcStatus", "All", and "None". Multiple categories can be specified,
"PortThreshold", "Other", "All", and "None". Multiple categories can be specified,
separated by commas.
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric-20.40 F8 Module for c-Class BladeSystem Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem